Table 4 Validation of developed immunostick test for screening of α-thalassemia 1 SEA type deletion carriers

From: Immunostick Test for Detecting ζ-Globin Chains and Screening of the Southeast Asian α-Thalassemia 1 Deletion

Immunostick test for ζ-globin chain PCR analysis for SEA 훼-thalassemia 1 Total
Positive Negative
Positive 53 17 70
Negative 0 78 78
Total 53 95 148
  1. Sensitivity (53/53) × 100 = 100%
  2. Specificity (78/95) × 100 = 82%
  3. Positive predictive value (53/70) × 100 = 76%
  4. Negative predictive value (78/78) × 100 = 100%